In a message dated 1/9/2008 9:02:58 A.M. Pacific Standard Time,
towertalk-request@contesting.com writes:
> I seem to recall at one time Phillystran recommended using cable clamps.
I'm not sure if this was done with the older style product.
This was for the newer current product before they had special Preformed
grips. They do NOT recommend using cable clamps - caused cold flowing of the
aramid fiber strands - except for the smallest size which doesn't have any
Preforms available.
The old style Phillystran was fairly stiff and used the potting heads.
The current product is flexible and you could tie it into a knot. Not
recommended obviously but a quick check of its flexibility.
Cheers,
Steve K7LXC