Hi,
Need my memory jogged! I believe I recall that
the kTB value, at near room temperature, and
in a 1 mHz bandwidth, the formula will calculate to be
-114 dBm of noise power -- is this correct? Or
close. If so, and the bw were narrowed to 1 kHz,
a 30 dB shrinkage, the noise power would then
be -144 dBm. These numbers seem about correct.
Appreciate a correction if I am not doing this right, hi.
Yes, the correct units must be used, degrees K, but
I have no reference out here to the value of Boltzman's
constant, B.
73, Jim KH7M