To: | topband@contesting.com |
---|---|
Subject: | Re: Topband: Any way to check isolation transformer for FCP |
From: | Andy - YL2QN <yl2qn.andy@gmail.com> |
Date: | Mon, 18 Jan 2016 11:52:00 +0200 |
List-post: | <topband@contesting.com">mailto:topband@contesting.com> |
Guido, >>> It sounds strange, because to have 45,6 uH with 20 turns the Al should be 1140. Thanks a lot. Sure I was wrong with inductance. For 20 turns: T-300A-2 AL=228, L=9.12uH T-300-2 AL=114, L=4.56uH To get same inductance on T-300-2 need to have 28T. But coupling will between primary and secondary will be changed. How much it critical ? Regards, Andy - YL2QN _________________ Topband Reflector Archives - http://www.contesting.com/_topband |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: Topband: Neutralizing your 833As, Mike Waters |
---|---|
Next by Date: | Re: Topband: FCC regulations, Roger D Johnson |
Previous by Thread: | Re: Topband: Any way to check isolation transformer for FCP, Guido Tedeschi |
Next by Thread: | Topband: 2016 Visalia Top Band Dinner, wb6rse1 |
Indexes: | [Date] [Thread] [Top] [All Lists] |