Isn't it in the TO-204-2 package, where the case is the "drain"?
________________________________
From: TenTec <tentec-bounces@contesting.com> on behalf of Michael Marx
<sndtubes@vacuumtubes.com>
Sent: Monday, November 20, 2017 12:09 PM
To: TenTec@contesting.com
Cc: TenTec@yahoogroups.com
Subject: [TenTec] Centurion Bias Transistor Follow on post
Guys,
I just posted a message about my Centurion with a bias problem. As I stated I
replaced the bias transistor which did not fix the problem. Here is something
interesting that I don’t understand. I bought 5 of them from Mouser. When I
measure the transistor junctions with my Fluke 87 meter in the diode function,
one junction seems normal as it measures .5 V in one direction and open in the
other. Normal, right? Now the other junction measures open in both directions.
It also measures open in ohmmeter mode. Could I have bought 5 bad
transistors? Is that even possible? What am I doing wrong in testing these
transistors? They are just an NPN bipolar transistor, right? FYI it is an
MJ15001G by ON. This is exactly what Ten Tec sent a few years ago when I had
to replace the transistor.
Very confused.
73
Mike WB0SND
Michael Marx
sndtubes@vacuumtubes.com
636-939-9190
SND Tube Sales
105 N. Division St.
Bonne Terre, MO 63628
_______________________________________________
TenTec mailing list
TenTec@contesting.com
https://nam03.safelinks.protection.outlook.com/?url=http%3A%2F%2Flists.contesting.com%2Fmailman%2Flistinfo%2Ftentec&data=02%7C01%7CDgparsons51%40hotmail.com%7C47dd07141ca940fcc8c608d530420f06%7C84df9e7fe9f640afb435aaaaaaaaaaaa%7C1%7C0%7C636467982654149427&sdata=pwMP24ZvzgIl4rgI1BT%2FvjjgT11GmwVmUejK3HQ1A1I%3D&reserved=0
_______________________________________________
TenTec mailing list
TenTec@contesting.com