I had the same problem a while ago. I had good results using a second
receiver. I adjusted the two balanced mod. pots until the carrier just
about disappeared on the second receiver. You probably should make sure
that the lsb bfo crystal is on frequency. In my case the problem came back.
I had to change the two pots. Its been fine since.
73, Ernie K2EP
----- Original Message -----
From: <W5OT@aol.com>
To: <tentec@contesting.com>
Sent: Wednesday, April 01, 2009 10:37 PM
Subject: [TenTec] Carrier null on Omni VI; SSB switching transient
> My Omni VI has a small bit of carrier showing on LSB that is not present
> on
> USB. Also there is a full output switching transient when I key the mike
> in
> LSB; it is less than half on USB.
>
> Can this alignment/null be performed with a minimum of test equipment? I
> don't have a service monitor capable of 1 Hz readout. I seem to remember
> some
> discussion on the switching transient a few years ago, so I will try to
> check
> the archives.
>
> 73, John