Hopefully your house is fed with metal pipe, not PVC like mine is...
73, and thanks,
Dave (NK7Z)
https://www.nk7z.net
ARRL Volunteer Examiner
ARRL Technical Specialist, RFI
ARRL Asst. Director, NW Division, Technical Resources
On 11/13/20 4:48 PM, K9MA wrote:
While I generally agree that the green (ground) wire should go through the CM choke,
here’s an exception: My gas water heater was shutting down whenever I was on
160. It has a grounding cord, but the ground is totally redundant because the tank is
tied into the copper plumbing. (That would not be the case with non-metallic
plumbing.) I made a choke with a two-wire extension cord, and left the green wire
open. No more cold showers.
73,
Scott K9MA
----------
Scott Ellington
--- via iPad