On 11/13/20 4:48 PM, K9MA wrote:
While I generally agree that the green (ground) wire should go through the CM choke, 
here’s an exception: My gas water heater was shutting down whenever I was on 
160. It has a grounding cord, but the ground is totally redundant because the tank is 
tied into the copper plumbing. (That would not be the case with non-metallic 
plumbing.) I made a choke with a two-wire extension cord, and left the green wire 
open. No more cold showers.

73,
Scott K9MA

----------

Scott Ellington

  --- via iPad