RFI
[Top] [All Lists]

[RFI] Device Generating RFI Fix

To: rfi@contesting.com
Subject: [RFI] Device Generating RFI Fix
From: WD8ARZ <wd8arz@ix.netcom.com>
Date: Mon, 7 Aug 2017 08:34:41 -0400
List-post: <mailto:rfi@contesting.com>
Many of today's electronics use AC Switching power supplies. That method avoids the use of transformers saving on cost, weight and size of the device. Instead 'switching' power supplies circuits are used. That method of chopping the a power source to achieve the voltage and current from the device as needed to run that equipment, does generate a lot of spurious signals. Some of them are radiated as radio frequency energy (RF). A lot of interference can be generated by such devices and be received by other devices, especially when other devices are close to a radiating piece of equipment.

Unfortunately, many such power supplies do not use a true on / off switch that mechanically disconnects the power supply from the a.c. mains. Thus turning the device "off" may not in fact remove power from the switching power supply. It is left running to support the 'instant on' feature. To remove the interference from such a device requires pulling the power cord out of the ac outlet to truly turn it off.

So when looking for a radiating interfering signal, pull the power cord to truly test if that device is the problem or not. Good luck on such a quest of find that type of interference .... 73 from Bill - WD8ARZ