Bad filter cap. Filter caps were designed to last 6 to 8 years.
Lee, w0vt
----- Original Message -----
From: "Charles Hedrick" <cchedrick@gmail.com>
To: amps@contesting.com
Sent: Saturday, November 15, 2014 9:37:49 PM
Subject: [Amps] Hunter 2000C issue
R9 keeps going open. Any ideas. It's the center feed to the cap string.
5 ohm 10 w wire wound. I had switched from 75m to 20m and was loading when
it went down the first time. I had 1450 PEP watts out on 75m SSB before I
switches it. Then I was loading it on my Dummy Antenna and R9 opened.
Help,
Cam
WA4JKW
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|