Starting a new project.
I'm collecting parts for a new HB 8877 amp. One really nice part
that I've recently acquired is a massive transformer for the HV
supply. This transformer came out of a commercial FM transmitter
that ran an 8877 at 1 kw continuous duty.
While that power supply used a choke-input filter in the HV supply, I
want to run the higher voltage obtained by a cap.-input filter. With
a cap.-input filter, however, the HV supply will be a tad over
4150VDC, using the "best" primary taps available. Can wire for
higher, but not any lower.
My question(s) is/are: How critical is Eimac's "absolute maximum
ratings" as far as plate voltage is concerned. I know that under
load, with acceptably regulation, the plate voltage will be about
where I want it at 3800V. Is the slightly-too-high potential on the
anode under no-load a problem? Or, should I just not worry about it
and "let 'er rip, tator chip".
Anyone have experience here?
73,
Charles - K5ZK