Your tubes are gas ie
> From: carlclawson@verizon.net
> To: amps@contesting.com
> Date: Sat, 13 Mar 2010 17:35:13 -0800
> Subject: [Amps] LK500ZB (2 x 3-500Z), most likely cause of zap/arc?
>
> Anyone have an idea of a favorite failure mode that would cause visible and
> audible arcing in the tube compartment? I'm trying to repair one. Put 10 or
> 20 watts drive to it with the tune controls at nominal settings, you get
> maybe 400 mA plate current. Then as soon as you start rotating the tune
> control...Zap! Followed by blown fuse. And blown grid meter shunt resistor.
>
> There's no visible damage, except the varnish is peeling in a few places on
> the plate choke. It doesn't look burnt or anything, but does that indicate a
> choke problem? Or just old age?
>
> >From what I've read on this reflector before, bad parasitic suppressors
> would be my first guess. But the benefit of your experience will be
> appreciated. I don't have a garage full of spare tubes, chokes, and other
> parts that I can swap in so I'd like to go with the best odds before I start
> buying stuff to try.
>
> 73 and thanks,
> Carl WS7L
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
_________________________________________________________________
Hotmail: Trusted email with Microsoft’s powerful SPAM protection.
http://clk.atdmt.com/GBL/go/210850552/direct/01/