On Jun 26, 2006, at 6:03 AM, Tom W8JI wrote:
> The original subject was the manual of the AL80 says to load
> to 550mA and then as a final step back off drive to obtain
> 400mA. This ensures the loading is heavy enough and grid
> current is proper to handle ALC overshoots common with
> exciters. That horrified a couple people, ...
I don't know why. With just a little bit of searching, I found a
3-500Z spec sheet that clearly shows constant current curves going as
high as 2.2 amps! (Here:<http://www.mif.pg.gda.pl/homepages/frank/
sheets/088/3/3-500Z.pdf>)
So much for the claim that the 3-500Z can't pass more than 420 mA....
Besides, if it offends people, they can just tune their amps some
other way.
I don't see what the big deal is.
Bill Coleman, AA4LR, PP-ASEL Mail: aa4lr@arrl.net
Quote: "Not within a thousand years will man ever fly!"
-- Wilbur Wright, 1901
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|