Mike Bondarev wrote:
>Thanks to all of you for your comments. GU-84B need 147CFM and GU-78B 
>need 165CFM airflow. But this is for full power plate dissipation 
>continuous key down. In SSB and CW you can have less. So I'll look for 
>Dayton 2C647, 4C006 and 4C446. I hope the quality of this blowers is 
>good for long time operations.
>
Remember that American blowers are rated for 60Hz supplies, and will 
give much less air output on European 50Hz supplies.


-- 
73 from Ian GM3SEK