List-post: | <mailto:amps@contesting.com> |
Mike Bondarev wrote: >Thanks to all of you for your comments. GU-84B need 147CFM and GU-78B >need 165CFM airflow. But this is for full power plate dissipation >continuous key down. In SSB and CW you can have less. So I'll look for >Dayton 2C647, 4C006 and 4C446. I hope the quality of this blowers is >good for long time operations. > Remember that American blowers are rated for 60Hz supplies, and will give much less air output on European 50Hz supplies. -- 73 from Ian GM3SEK _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |