Tom said:
"You can find this discussed in Care and Feeding of Power Grid Tubes by
Varian, ..."
Rich replied:
"** Not in my copy of "Care and Feeding ..."
Rich, it is in my copy. Page 68 of the third printing,1978, under 4.3.2
What Makes a Tube Linear. Seems to me that was one of the points of the
book.
Colin K7FM
-------------------
Rich's reply:
** "Care and Feeding of Power Grid Tubes", p. 68, 4.3.2, "What Makes a
Tube Linear" refers to p.69, "Ideal grid-plate (anode) transfer curve for
class AB operation". After looking at the curves for a 3-500Z, it seems
to me that the 3-500Z does not have ideal transfer characteristics
because its emission begins to limit above the 1.2A-peak curve (c.400mA
avg) due to the emissive limit of its 75w filament.
Colin -- life would be easier on the AMPS group if you enabled the
auto-attribution markers option in your e-mailler app.
- R. L. Measures, a.k.a. Rich..., 805.386.3734, AG6K,
www.vcnet.com/measures.