In a message dated 2/3/01 1:57:31 AM Eastern Standard Time, 2@vc.net writes:

> 
>  >
>  >One popular HF amp today (I own one) is designed so that when one flips
>  >the power switch the fil, fan and HV all come on.  There is no CW/SSB
>  >switch as on some of the older amps.  i.e. SB-220 and Drake L-4B (I
>  >recall).  This amp runs a pr of 3-500Zs with a key down output of 1500+
>  >watts.  Duty cycle is 50% or 10 min on and 10 min off.  The standby
>  >switch only defeats the T/R switching.  And yes, it's full QSK.
>  >
>  >Now, my 8877 on 144 MHz is a different animal.  It takes a full 1 min
>  >for the heaters to get the cathode up to operating temp.  Here, it's
>  >smart to wait til the thing warms up.
>  
>  1 minute is way short of the recommended warm-up time.
>  
>  .
>  
>  -  Rich..., 805.386.3734, www.vcnet.com/measures.  
>  end
>  =========================================================

Eimac actually recommends 5 minutes.

Dave, WT8R


--