1. Topband: Shack wiring & noise (score: 1)
Author: ford@cmgate.com (Ford Peterson)
Date: Sun, 12 Jan 2003 01:36:52 -0600
I made an attempt at the NAQP-CW today. Great fun. During the evening hours, I noticed something about noise on 160M and 80M that may help me achieve better S/N. It's very cold outside--about 0 degre
/archives//html/Topband/2003-01/msg00063.html (8,468 bytes)

2. Topband: Shack wiring & noise (score: 1)
Author: Tom Rauch" <w8ji@contesting.com (Tom Rauch)
Date: Sun, 12 Jan 2003 11:54:51 -0500
seconds Very large electric motors have a starting capacitor that switches in only when the motor is at rest, and is initially activated. Most furnace and air conditioning motors have a "run" capaci
/archives//html/Topband/2003-01/msg00065.html (8,944 bytes)

3. Topband: Shack wiring & noise (score: 1)
Author: k1fz@prexar.com (B. Clark)
Date: Sat, 11 Jan 2003 12:13:38 -0500
Hi Ford, Noise is best stopped at its source. (A filter at the furnace) I had this problem at another QTH years ago. Not only can the wiring conduct the noise like a poorly matched transmission line,
/archives//html/Topband/2003-01/msg00066.html (8,124 bytes)

4. Topband: Shack wiring & noise (score: 1)
Author: ford@cmgate.com (Ford Peterson)
Date: Sun, 12 Jan 2003 21:48:42 -0600
Wow! Lots of good responses. Most want me to disconnect the furnace fan. Well, I just completed a better experiment. The "shack" is a separate metal building on my property with it's own electrical p