- 1. Topband: Ground rods vs radials (score: 1)
- Author: "Donald Chester" <k4kyv@hotmail.com>
- Date: Sat, 21 Aug 2004 15:21:54 +0000
- ...And I'm not sure I buy into the 'penetrate the soil very far' either. "Very Far" is clearly not a technical term, but the suggestion is that a few inches is all you get. I'm not buying it. ...>Bas
- /archives//html/Topband/2004-08/msg00041.html (8,202 bytes)
- 2. Re: Topband: Ground rods vs radials (score: 1)
- Author: "Tom Rauch" <w8ji@contesting.com>
- Date: Sun, 22 Aug 2004 11:11:02 -0400
- for lightning is so short that to the ground rod There is a complex soup of things going on with a ground rod driven into earth. First, the soil is almost never a homogenous media. Second, the conta