Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*Topband\:\s+Confusion\s+in\s+ON4UN\'s\s+Low\s+Band\s+DXing\s+radiallengthcalculations\.\s*$/: 2 ]

Total 2 documents matching your query.

1. Topband: Confusion in ON4UN's Low Band DXing radiallengthcalculations. (score: 1)
Author: k1fz@myfairpoint.net
Date: Fri, 19 Dec 2014 15:55:57 -0500
  The on/in ground wire- as RF advances toward the normal 1/4 wave high impedance (/high voltage point)  finds itself tightly coupled to a +- 350 ohm typical ground resistance. 'Hogs the voltage righ
/archives//html/Topband/2014-12/msg00335.html (8,572 bytes)

2. Re: Topband: Confusion in ON4UN's Low Band DXing radiallengthcalculations. (score: 1)
Author: k1fz@myfairpoint.net
Date: Sun, 21 Dec 2014 10:23:48 -0500
Look at the radial field as a FAT inductor. A fat tower has a lower Q and wider bandwidth, lower impedance at the top/far end.   73 Bruce-=k1fz.   GM BRIAN... I HAVE BEEN OFF TOP BAND FOR SEVERAL YEA
/archives//html/Topband/2014-12/msg00360.html (10,803 bytes)


This search system is powered by Namazu