Search String: Display: Description: Sort:

Results:

References: [ +from:k1ttt.dave@gmail.com: 7 ]

Total 7 documents matching your query.

1. [Yaesu] some stuff sold, more to go! (score: 1)
Author: "David Robbins" <k1ttt.dave@gmail.com>
Date: Mon, 03 Jun 2019 10:42:05 -0500
Need to sell off excess spares to finish upgrade to FT-2000's... There will be two more FT-1000mp's available when that is done. Yaesu DMU-2000 with new in box SCP card, manual, cables. $500 shipped.
/archives//html/Amps/2019-06/msg00007.html (8,268 bytes)

2. Re: [Amps] HF-2500 T/R Relay (score: 1)
Author: "David Robbins" <k1ttt.dave@gmail.com>
Date: Thu, 04 Jun 2020 15:32:42 -0500
Ah, proud owner of a commander hf-2500... here are some links for you: Improved relay replacement: http://wiki.k1ttt.net/2010-Maintenance-and-Upgrade-Blog.ashx#hf2500relay something to do while you h
/archives//html/Amps/2020-06/msg00009.html (8,830 bytes)

3. Re: [Amps] ACOM Director software (score: 1)
Author: "David Robbins" <k1ttt.dave@gmail.com>
Date: Mon, 03 Aug 2020 07:30:51 -0500
In order to do power on/off you need the optional RPON module from ACOM. If you have that then you can turn the amp on and off remotely. A bug in the amp, I think, prevents you from clearing the PROT
/archives//html/Amps/2020-08/msg00018.html (8,050 bytes)

4. [Amps] ft-2000 vs pgxl (score: 1)
Author: <k1ttt.dave@gmail.com>
Date: Fri, 3 Sep 2021 10:31:45 -0400
A couple related questions for both Yaesu and amps guys. Just had to send pgxl back for replacement of an ldmos. They say one possible cause of ldmos failure is not allowing for at least 20msec betwe
/archives//html/Amps/2021-09/msg00000.html (7,420 bytes)

5. Re: [Amps] Commander 2500 toroid (score: 1)
Author: <k1ttt.dave@gmail.com>
Date: Sat, 20 Aug 2022 18:08:21 -0400
I have several spares of those cores. They are micrometals T225-2b cores. And yes, overheating can crack the cores, at least a couple that I deconstructed showed a hot spot and obvious crack. The bas
/archives//html/Amps/2022-08/msg00027.html (8,848 bytes)

6. Re: [Amps] Alpha 87A - strange power related issue (score: 1)
Author: <k1ttt.dave@gmail.com>
Date: Mon, 10 Oct 2022 10:00:07 -0400
Does that perhaps use solid state switches to turn on the main power? I have seen them (in a different amp) get leaky which produced a low control voltage when they were supposed to be off, something
/archives//html/Amps/2022-10/msg00019.html (11,850 bytes)

7. Re: [Amps] Starting up a NEW Henry amp (score: 1)
Author: <k1ttt.dave@gmail.com>
Date: Fri, 17 Nov 2023 14:35:14 -0500
Yes, most likely relays causing loss of rx signal. Another quick test to confirm relay dirt/corrosion is to leave the amp in standby and put 100w through the amp, this usually temporarily burns a bet
/archives//html/Amps/2023-11/msg00025.html (13,528 bytes)