- 1. easy off guy attachment? (score: 1)
- Author: n2qt@pipeline.com (Mark Sihlanick)
- Date: Mon, 16 Dec 1996 03:10:00 GMT
- I'm planning to erect 66 ft of rohn 25 to use with a Hazer. With this height I'll need two sets of guys and the lower set will of course need to come off to allow the Hazer to pass. I want to minimiz
- /archives//html/Towertalk/1996-12/msg00232.html (7,107 bytes)
- 2. easy off guy attachment? (score: 1)
- Author: K7LXC@aol.com (K7LXC@aol.com)
- Date: Mon, 16 Dec 1996 11:02:17 -0500
- Hi, Mark -- Rohn 25G typically requires 3/16 inch EHS guy wire which is rated at 3990 pounds breaking strength and should be tenisoned at 10% of ultimate breaking strength, or approximately 400 pound
- /archives//html/Towertalk/1996-12/msg00240.html (8,131 bytes)
- 3. easy off guy attachment? (score: 1)
- Author: w7ni@teleport.com (Stan Griffiths)
- Date: Tue, 17 Dec 1996 03:29:52 -0800 (PST)
- I am having a little problem envisioning this process. For the Hazer to pass the lower guy point, I am guessing the guys have to actually be removed from the tower, right? Just removing them from th
- /archives//html/Towertalk/1996-12/msg00261.html (7,997 bytes)
This search system is powered by
Namazu