Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[TowerTalk\]\s+Vertical\s+Monopole\s+Modeling\s+Problem\s*$/: 3 ]

Total 3 documents matching your query.

1. [TowerTalk] Vertical Monopole Modeling Problem (score: 1)
Author: rudder1@ibm.net (Malcolm Clark)
Date: Tue, 17 Mar 1998 08:05:53 +0000
While playing with the evaluation copy of NEC4WIN95 I attempted to model a 40 meter vertical monopole consisting of 35 feet of Rohn 25G with a drop wire two foot off the tower. The result showed a so
/archives//html/Towertalk/1998-03/msg00299.html (8,036 bytes)

2. [TowerTalk] Vertical Monopole Modeling Problem (score: 1)
Author: mainhart@juno.com (Rick Mainhart)
Date: Tue, 17 Mar 1998 13:29:42 -0500
Malcolm, To work around the 5:1 diameter ratio, model two Rohn 25G towers side by side, connected at the top. Better yet, model (and build) the drop wire as three wires spaced just like the Rohn 25G
/archives//html/Towertalk/1998-03/msg00310.html (8,213 bytes)

3. [TowerTalk] Vertical Monopole Modeling Problem (score: 1)
Author: n4zr@contesting.com (Pete Smith)
Date: Tue, 17 Mar 1998 13:56:42 -0500
However, be aware that such a shunt feed will demonstrate considerably different feedpoint characteristics than one where the shunt conductor is tiny relative to the tower -- see ON4UN's book for som
/archives//html/Towertalk/1998-03/msg00312.html (7,838 bytes)


This search system is powered by Namazu