1. [TowerTalk] One less than optimum guy wire (score: 1)
Author: dave arruzza via TowerTalk <towertalk@contesting.com>
Date: Thu, 8 Dec 2022 21:27:12 +0000 (UTC)
I need to guy a Rohn 25 tower  60' high 2 sets of guys per Rohn manual  1 set needs to be 36' not the standard 48' out from the tower Comments please  73Dave   W1CTN _________________________________
/archives//html/Towertalk/2022-12/msg00092.html (7,534 bytes)

2. Re: [TowerTalk] One less than optimum guy wire (score: 1)
Author: Doug Christensen <auriga1usa@gmail.com>
Date: Thu, 8 Dec 2022 15:44:47 -0600
It depends on the load. The EPA (extended profile area). Personally I would install 6 guy wires at a 35 angle from the tower. At 50',and. at 30'. 73 Doug, WB1E _______________________________________
/archives//html/Towertalk/2022-12/msg00093.html (7,649 bytes)

3. Re: [TowerTalk] One less than optimum guy wire (score: 1)
Author: Mpridesti via TowerTalk <towertalk@contesting.com>
Date: Thu, 8 Dec 2022 16:56:50 -0500
Dave Is this tower we discussed? 60 ft tower guyed at 25 and 50 for what you are planning. Also given your short guy point situation maybe consider 4 way guys instead of 3? Can use short guy points w
/archives//html/Towertalk/2022-12/msg00094.html (9,605 bytes)

4. Re: [TowerTalk] One less than optimum guy wire (score: 1)
Author: Tony Brock-Fisher via TowerTalk <towertalk@contesting.com>
Date: Thu, 8 Dec 2022 17:07:05 -0500
Been there, done that, tower is still standing. 78' Rohn 45. Specs call for 2 sets anchored at 56' from the base. On anchor was constrained by property line to ~30'. I had a PE do the design work (he
/archives//html/Towertalk/2022-12/msg00095.html (8,187 bytes)