Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[TowerTalk\]\s+Need\s+help\s+with\s+Tailtwister\s*$/: 5 ]

Total 5 documents matching your query.

1. [TowerTalk] Need help with Tailtwister (score: 1)
Author: kq2m@kq2m.com
Date: Fri, 19 Nov 2021 15:26:50 -0600
Hi, I have a sidemounted T2X @ 37' which turns a 5L 105CA. The rotator is turning fine but the direction indication got erratic very briefly and then stopped indicating - with the needle pegged to th
/archives//html/Towertalk/2021-11/msg00084.html (7,775 bytes)

2. Re: [TowerTalk] Need help with Tailtwister (score: 1)
Author: John Simmons <jasimmons@pinewooddata.com>
Date: Fri, 19 Nov 2021 16:23:58 -0600
Bob, The first thing I would do is perform tests described in the manual. You will check the control box voltages on the rotor wiring and the resistance of the rotor from the ground. Documentation is
/archives//html/Towertalk/2021-11/msg00090.html (9,237 bytes)

3. Re: [TowerTalk] Need help with Tailtwister (score: 1)
Author: "Joe Subich, W4TV" <lists@subich.com>
Date: Fri, 19 Nov 2021 17:33:40 -0500
I seem to remember something about an internal fuse in the control box - could that be a source of the problem? The fuse on the meter supply is shown on the schematic in your T2X manual. with the nee
/archives//html/Towertalk/2021-11/msg00091.html (10,022 bytes)

4. Re: [TowerTalk] Need help with Tailtwister (score: 1)
Author: kq2m@kq2m.com
Date: Sat, 20 Nov 2021 12:51:10 -0600
Hi Joe, As it turns out it was both the control box and the rotator. After checking the voltage readings between pins 3-7, 1-2. 1-5 and 1-6 (all zero) and comparing against 13.5 v between 3-7 on a go
/archives//html/Towertalk/2021-11/msg00094.html (11,953 bytes)

5. Re: [TowerTalk] Need help with Tailtwister (score: 1)
Author: kq2m@kq2m.com
Date: Sat, 20 Nov 2021 12:52:29 -0600
Hi John, Thank you for your reply and the suggeston. I performed the tests in the manual as mentioned in my reply to W4TV. Tnx & 73 Bob, KQ2M The first thing I would do is perform tests described in
/archives//html/Towertalk/2021-11/msg00095.html (9,239 bytes)


This search system is powered by Namazu