Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[TowerTalk\]\s+Engineering\s+closer\-in\s+guys\s*$/: 6 ]

Total 6 documents matching your query.

1. [TowerTalk] Engineering closer-in guys (score: 1)
Author: Matthew Kaufman <matthew@matthew.at>
Date: Wed, 2 Sep 2020 18:52:37 -0700
TL; DR: fire got my tower, cant replace at same height with stock guy anchor distance. I had a Rohn 55 tower that was built in 1971 as 150 high with 4 levels of guys and anchors 120 from the base. So
/archives//html/Towertalk/2020-09/msg00018.html (7,614 bytes)

2. Re: [TowerTalk] Engineering closer-in guys (score: 1)
Author: Tony Brock-Fisher via TowerTalk <towertalk@contesting.com>
Date: Wed, 2 Sep 2020 22:44:21 -0400
Yes, I had a tower engineered to have one set of guys anchored closer in than the other two, and closer than the Rohn guidelines. I ended up with 78' of Rohn 45G. The Rohn spec called for two levels
/archives//html/Towertalk/2020-09/msg00019.html (8,442 bytes)

3. Re: [TowerTalk] Engineering closer-in guys (score: 1)
Author: Mike Lyon <mike.lyon@gmail.com>
Date: Wed, 2 Sep 2020 19:50:43 -0700
Which brings up another good point. Anyone know of a good PE for towers? -Mike _______________________________________________ _______________________________________________ TowerTalk mailing list T
/archives//html/Towertalk/2020-09/msg00020.html (8,434 bytes)

4. Re: [TowerTalk] Engineering closer-in guys (score: 1)
Author: jimlux <jimlux@earthlink.net>
Date: Wed, 2 Sep 2020 20:27:34 -0700
I had a Rohn 55 tower that was built in 1971 as 150 high with 4 levels of guys and anchors 120 from the base. Some ten years later they put two more sections on, making it 170, and added a 5th guy le
/archives//html/Towertalk/2020-09/msg00021.html (9,735 bytes)

5. Re: [TowerTalk] Engineering closer-in guys (score: 1)
Author: Jim Brown <jim@audiosystemsgroup.com>
Date: Wed, 2 Sep 2020 21:44:23 -0700
On 9/2/2020 6:52 PM, Matthew Kaufman wrote: I had a Rohn 55 tower that was built in 1971 as 150 high with 4 levels of guys and anchors 120 from the base. Some ten years later they put two more sectio
/archives//html/Towertalk/2020-09/msg00022.html (8,619 bytes)

6. Re: [TowerTalk] Engineering closer-in guys (score: 1)
Author: john@kk9a.com
Date: Thu, 03 Sep 2020 06:21:02 -0500
The 80% anchor distance is just a general guideline, many towers are safely built with much closer guy anchors. Rohn engineering should be able to help you with this. It may be as simple as just usin
/archives//html/Towertalk/2020-09/msg00023.html (8,704 bytes)


This search system is powered by Namazu