- 1. Topband: Skin effect on RG6U at top band (score: 1)
- Author: jeremy maris <jeremy@maris.plus.com>
- Date: Mon, 31 Jan 2011 10:19:15 +0000
- We've used 1 km of coax to feed a remote Beverage (3 wavelength, 60 degrees, for VK and far east). 750m of the coax is RG6U, with copper braid. The results were poor, despite a 10dB head amplifier at
- /archives//html/Topband/2011-01/msg00161.html (7,353 bytes)
- 2. Re: Topband: Skin effect on RG6U at top band (score: 1)
- Author: "ZR" <zr@jeremy.mv.com>
- Date: Mon, 31 Jan 2011 10:57:34 -0500
- CATV requirements start at 5MHz so I have my doubts that the cable is at fault. Ive heard a similar complaint from Australia with copper braid RG-6 so wonder if it is a non USA product problem. Maybe
- /archives//html/Topband/2011-01/msg00164.html (9,762 bytes)
- 3. Re: Topband: Skin effect on RG6U at top band (score: 1)
- Author: "Bill Wichers" <billw@waveform.net>
- Date: Mon, 31 Jan 2011 14:52:03 -0500
- It is typical for the loss on the CCS (Copper Clad Steel) center conductor RG6 cables to be a bit higher than you'd expect at the low frequencies, but it's usually not super significant. For example,