1. Re: Topband: RFI - and lots of it - final status (score: 1)
Author: Jim Murray via Topband <topband@contesting.com>
Date: Wed, 4 Nov 2015 03:06:15 +0000 (UTC)
Electricians worked today on the house grounding the entrance panel and checking out all of the wiring.  Now, everything is grounded to the panel.   They ran a line from the grounding directly to the
/archives//html/Topband/2015-11/msg00027.html (8,259 bytes)

2. Re: Topband: RFI - and lots of it - final status (score: 1)
Author: Jim Brown <jim@audiosystemsgroup.com>
Date: Tue, 3 Nov 2015 20:01:11 -0800
On Tue,11/3/2015 7:06 PM, Jim Murray via Topband wrote: Electricians worked today on the house grounding the entrance panel and checking out all of the wiring. Now, everything is grounded to the pane
/archives//html/Topband/2015-11/msg00028.html (7,898 bytes)

3. Re: Topband: RFI - and lots of it - final status (score: 1)
Author: bruce whitney via Topband <topband@contesting.com>
Date: Wed, 4 Nov 2015 14:01:36 +0000 (UTC)
Just a FYI that comes from 40 years in the utility business. A frequent (I want to say most common but don't have any data to prove it) problem is loose split bolt connectors connecting the drop to t
/archives//html/Topband/2015-11/msg00029.html (9,195 bytes)

4. Re: Topband: RFI - and lots of it - final status (score: 1)
Author: Mike Waters <mikewate@gmail.com>
Date: Wed, 4 Nov 2015 09:32:51 -0600
Really! The low voltage, high current connections, whodathoughtit? Lately, when my central AC kicks on, the lights dim. I was going to start by measuring the voltage drop in the breaker panel, but pe
/archives//html/Topband/2015-11/msg00030.html (7,929 bytes)