1. [TenTec] Paragon II meter (score: 1)
Author: Mike Golini <mgolini@gmail.com>
Date: Fri, 9 Aug 2019 13:35:06 -0400
My SWR/WATT meter on my Paragon II is gone - needle stays in the middle regardless of mode switch position and RF Anyone know a suitable replacement or NOS ? The meter movement should show S9 with de
/archives//html/TenTec/2019-08/msg00028.html (6,635 bytes)

2. Re: [TenTec] Paragon II meter (score: 1)
Author: Gary Follett <dukeshifi@comcast.net>
Date: Fri, 9 Aug 2019 14:10:16 -0500
I have several of these. However, before you replace it, remove the plastic front cover of the meter. Then turn the pivot screw gently CCW about 1/4 turn or less. Then check to see if it still sticks
/archives//html/TenTec/2019-08/msg00029.html (7,648 bytes)

3. Re: [TenTec] Paragon II meter (score: 1)
Author: Stuart Rohre <Rohre@arlut.utexas.edu>
Date: Fri, 9 Aug 2019 16:30:06 -0500
Mike, don't give up on your meter if you can CAREFULLY remove it from the dase cover and see if the meter will deflect by blowing puffs of air to it, and see if needle is unglued, or stuck to somethi
/archives//html/TenTec/2019-08/msg00030.html (7,742 bytes)

4. Re: [TenTec] Paragon II meter (score: 1)
Author: Jim Bell <portdoverbells@hotmail.com>
Date: Sat, 10 Aug 2019 15:50:42 +0000
Hi, I just saw your post. I had the same problem where the needle would stay up mid scale. I took the plastic cover off and washed it in dish washing soap as it was holding a static charge that would
/archives//html/TenTec/2019-08/msg00031.html (9,353 bytes)

5. Re: [TenTec] Paragon II meter (score: 1)
Author: Gary Follett <dukeshifi@comcast.net>
Date: Sat, 10 Aug 2019 11:12:39 -0500
I have had many that still stuck with the meter face removed and loosening the pivot fixed all of them. 73 Gary W0DVN _______________________________________________ TenTec mailing list TenTec@contes
/archives//html/TenTec/2019-08/msg00032.html (10,404 bytes)

6. Re: [TenTec] Paragon II meter (score: 1)
Author: Mike Golini <mgolini@gmail.com>
Date: Sun, 11 Aug 2019 19:31:25 -0400
Thank you to all who answered my inquiry. The needle was indeed stuck with no foreign objects impeding movement or static holding it in place. I took the suggestion of turning pivot screw and now eve