Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[TenTec\]\s+Paragon\s+II\s+and\s+SWR\s+meter\s+reading\s*$/: 6 ]

Total 6 documents matching your query.

1. [TenTec] Paragon II and SWR meter reading (score: 1)
Author: ARDUJENSKI@aol.com
Date: Wed, 9 Aug 2006 10:45:43 EDT
I noticed that not in all cases will the meter (set to SWR) in the Paragon II read exactly the same as that is the 238 ATU. By the way the 238 and the Paragon are connected by an 18 inch quality jump
/archives//html/TenTec/2006-08/msg00386.html (8,154 bytes)

2. Re: [TenTec] Paragon II and SWR meter reading (score: 1)
Author: "Denton" <denton@oregontrail.net>
Date: Wed, 9 Aug 2006 07:51:54 -0700
I notice the same on this end....Paragon II, 238B atu and MFJ-259B analyzer. Also, my Mirage MP-2 wattmeters indicate a different power output reading from the rig and atu if other than full power ou
/archives//html/TenTec/2006-08/msg00387.html (9,421 bytes)

3. Re: [TenTec] Paragon II and SWR meter reading (score: 1)
Author: "Denton" <denton@oregontrail.net>
Date: Wed, 9 Aug 2006 07:54:56 -0700
A subnote...if I connect my Mirage MP-1 line sensor directly in back of my Paragon II, then the swr readings on the MP-2 and rig will jive...even on 10 meters. -- Original Message -- From: "Denton" <
/archives//html/TenTec/2006-08/msg00388.html (10,048 bytes)

4. Re: [TenTec] Paragon II and SWR meter reading (score: 1)
Author: "M. P. Haynes" <k4beh@juno.com>
Date: Wed, 9 Aug 2006 11:03:18 -0400
Alan, Hello again. I have similar symptoms on the SWR meter on my OMNI VI+. With the RF gain at max the SWR meter will not go to zero but rests at about 2:1 SWR even though my 238 reads zero reflecte
/archives//html/TenTec/2006-08/msg00389.html (9,406 bytes)

5. Re: [TenTec] Paragon II and SWR meter reading (score: 1)
Author: Tommy <aldermant@alltel.net>
Date: Wed, 09 Aug 2006 13:28:23 -0400
Pat and Allen and Denton.... What you are seeing is pretty normal, with the exception of the AGC or the (rcvr) RF gain affecting the readings. First it's helpful to realize that you are using ham equ
/archives//html/TenTec/2006-08/msg00406.html (13,462 bytes)

6. Re: [TenTec] Paragon II and SWR meter reading (score: 1)
Author: "Dr. Gerald N. Johnson" <geraldj@storm.weather.net>
Date: Tue, 15 Aug 2006 13:54:28 -0500
Cascading SWR meters is a lot like carrying two watches. With one you could be sure of the time or the reading, but two are never going to agree. Each SWR meter shows what it sees at its output. But
/archives//html/TenTec/2006-08/msg00477.html (10,692 bytes)