- 1. [TenTec] Orion 565 XMIT alignment (score: 1)
- Author: art N4UC <n4uc@hotmail.com>
- Date: Sat, 5 Nov 2016 05:46:06 +0000
- Does anyone have the procedure to set the PWR, ALC, REF, etc... pots on the A5 board? Thanks in advance, 73 Art N4UC _______________________________________________ TenTec mailing list TenTec@contest
- /archives//html/TenTec/2016-11/msg00037.html (6,646 bytes)
- 2. Re: [TenTec] Orion 565 XMIT alignment (score: 1)
- Author: Mike Schatzberg <cherokeehillfarm@earthlink.net>
- Date: Sat, 5 Nov 2016 08:11:37 -0400
- Take a look on my page. It was written for the 566 and may help. http://home.earthlink.net/~cherokeehillfarm/id2.html 73, Mike W2AJI Sent from my iPhone ______________________________________________
- /archives//html/TenTec/2016-11/msg00040.html (8,061 bytes)
- 3. Re: [TenTec] Orion 565 XMIT alignment (score: 1)
- Author: art N4UC <n4uc@hotmail.com>
- Date: Sat, 5 Nov 2016 19:02:25 +0000
- Thanks a lot Mike, that answers the ALC aspect of the question. Just for clarification though, you say to set the ALC SET to where the actual RF output as measured by an external wattmeter is about 1
- /archives//html/TenTec/2016-11/msg00048.html (10,761 bytes)
- 4. Re: [TenTec] Orion 565 XMIT alignment (score: 1)
- Author: Carl Moreschi <n4py3@earthlink.net>
- Date: Sat, 05 Nov 2016 16:48:33 -0400
- Art, I believe you are correct. I would set the ALC pot for 100 watts and not 110. The power indicator is supposed to read watts and not percentage. If you exceed 100 watts, you signal will start to
- /archives//html/TenTec/2016-11/msg00053.html (11,891 bytes)
- 5. Re: [TenTec] Orion 565 XMIT alignment (score: 1)
- Author: Mike Schatzberg <cherokeehillfarm@earthlink.net>
- Date: Sat, 5 Nov 2016 16:49:02 -0400
- Yes, you can calibrate the display in watts, average or just key down. I used 100 watts and calibrated there. 73, Mike W2AJI Sent from my iPhone _______________________________________________ TenTec
- /archives//html/TenTec/2016-11/msg00054.html (12,214 bytes)
- 6. Re: [TenTec] Orion 565 XMIT alignment (score: 1)
- Author: Mike Schatzberg <cherokeehillfarm@earthlink.net>
- Date: Sat, 5 Nov 2016 17:14:30 -0400
- The information in the manual for adjusting the alc level with the led is incorrect also. You will have no problem with the speech processor either if you adjust everything as per the article. Amateu
- /archives//html/TenTec/2016-11/msg00055.html (11,251 bytes)
- 7. Re: [TenTec] Orion 565 XMIT alignment (score: 1)
- Author: art N4UC <n4uc@hotmail.com>
- Date: Mon, 7 Nov 2016 22:09:42 +0000
- Thanks to both of you. It should have been straightforward but for some reason I wasn't having any luck. This helps a lot. 73, Art N4UC The information in the manual for adjusting the alc level with
- /archives//html/TenTec/2016-11/msg00080.html (14,781 bytes)