1. [TenTec] OMNI VI Model 563 -- no digital readout (score: 1)
Author: Gregory Smith <gsmith_007@msn.com>
Date: Sat, 16 Feb 2019 16:14:47 +0000
Repeat problem on my Omni VI, Model 563 -- no digital display. First repair: No digital display or digital LED functions. No clock or data on uP pins 7 & 8. I replaced uP with gold plated quality soc
/archives//html/TenTec/2019-02/msg00043.html (7,596 bytes)

2. Re: [TenTec] OMNI VI Model 563 -- no digital readout (score: 1)
Author: Peter Bertini <radioconnection@gmail.com>
Date: Sat, 16 Feb 2019 13:42:43 -0500
Lamp intensity is controlled by the logic board. First thing I would check is to see if the 20 MHz oscillator is generating time base signals on the 7474 divider. Next, I would want to see clock puls
/archives//html/TenTec/2019-02/msg00045.html (7,232 bytes)