- 1. [TenTec] Argo V calibration (score: 1)
- Author: Rsoifer@aol.com
- Date: Sat, 15 Aug 2009 11:07:29 EDT
- Hi, My Argo V (with TCXO) reads 100 Hz low, i.e. 10 MHz WWV zero-beats at a reading of 9999.900. It isn't a warm-up drift problem as the reading is quite stable with time, well within the spec of 3 p
- /archives//html/TenTec/2009-08/msg00125.html (6,621 bytes)
- 2. Re: [TenTec] Argo V calibration (score: 1)
- Author: wa3fiy@radioadv.com
- Date: Sat, 15 Aug 2009 12:21:51 -0400
- Hi Ray, I've not had that problem with my Argonaut V but I did improve the calibration on my Pegasus a while back. I suspect the situation is very similar. It sounds like the TCXO is off a little bit
- /archives//html/TenTec/2009-08/msg00126.html (8,074 bytes)
- 3. Re: [TenTec] Argo V calibration (score: 1)
- Author: wa3fiy@radioadv.com
- Date: Sat, 15 Aug 2009 13:42:36 -0400
- Ray, I just checked my Argonaut V after a 10 minute warm-up and find the frequency error at 10 Mhz is 6.8 hz. I have not done a calibration on this rig and being under 10 hz, don't think I will even
- /archives//html/TenTec/2009-08/msg00127.html (9,829 bytes)
- 4. Re: [TenTec] Argo V calibration (score: 1)
- Author: Rsoifer@aol.com
- Date: Sat, 15 Aug 2009 13:49:17 EDT
- Hi Lee, That sounds like it could be the problem. Where is the TCXO trimmer located in the Argo V? Tnx, Ray In a message dated 8/15/2009 5:42:36 P.M. GMT Standard Time, wa3fiy@radioadv.com writes: Ra
- /archives//html/TenTec/2009-08/msg00128.html (9,457 bytes)