- 1. [TenTec] Centaur amp (score: 1)
- Author: phil greene <trapperpg@gmail.com>
- Date: Sat, 25 Oct 2025 23:02:26 -0400
- New to me Centaur amp with 572 tubes of unknown health. Only has output on 80 meters (~500w) 10-40 meters have plate and grid current but no output Load capacitor has no effect on any band Tuning cap
- /archives//html/TenTec/2025-10/msg00001.html (7,278 bytes)
- 2. Re: [TenTec] TenTec Digest, Vol 271, Issue 2 (score: 1)
- Author: Phil Greene <trapperpg@gmail.com>
- Date: Mon, 27 Oct 2025 00:04:48 +0000
- Centaur Amp After close inspection against schematic, the only thing I can find is R1 on the input board is a 50 ohm 25 watt instead of the called for 150 ohm 25 watt. I skipped past it on the first
- /archives//html/TenTec/2025-10/msg00007.html (12,714 bytes)