Search String: Display: Description: Sort:

Results:

References: [ +from:mike.hyder.n4nt@charter.net: 49 ]

Total 49 documents matching your query.

21. Re: [TenTec] Birdie on 20 Meters Ten Tec Corsair II (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Mon, 30 May 2005 08:36:29 -0400
Do you hear it both with an antenna connected and without an antenna? Have you found any signal weaker than the birdies? 73, Mike N4NT I have noticed a birdie on 20 meters on the frequencies of 14.22
/archives//html/TenTec/2005-05/msg00593.html (7,879 bytes)

22. Re: [TenTec] Model 961 Power Supply (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Mon, 11 Apr 2005 19:49:18 -0400
The Argosy relies upon the power supply for current limiting. The Argosy needs about 10 amps while the 961 is probably set for about 20 amps. The Argosy's final transistors are scarce as hens' teeth.
/archives//html/TenTec/2005-04/msg00300.html (8,139 bytes)

23. Re: [TenTec] Corsair II (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Sat, 5 Mar 2005 11:35:33 -0500
is there a C3? Is there a typo error in the Corsair II manual concerning the digital readout adjustment? My manual says to adjust the readout to 14,000 by adjusting R3.. My schematic shows R3 to be f
/archives//html/TenTec/2005-03/msg00171.html (7,678 bytes)

24. Re: [TenTec] digital triton IV qsk issue (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Sun, 6 Mar 2005 17:03:22 -0500
Hi, Mark-- I've never compared the analog with the digital but for me the digital was just fine for QSK. Maybe I'm not a purist? About that "drop out delay time" adjustment: the rigs have a larger re
/archives//html/TenTec/2005-03/msg00196.html (8,393 bytes)

25. Re: [TenTec] TTBroadband Terminated V Antenna (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Mon, 7 Mar 2005 01:02:39 -0500
If nobody has mentioned it, that antenna may only be rated for transmitter output power on the order of 100 watts and not for kilowatt levels. At least that's what they told me in September 2003. 73,
/archives//html/TenTec/2005-03/msg00209.html (8,333 bytes)

26. Re: [TenTec] mnodel 262g (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Mon, 7 Mar 2005 01:06:47 -0500
Hi, John-- The 262G supply was apparently not designed to be used in an RF environment. Ten-Tec had some different modifications that one could try to get that VOX to work properly and I'm pretty sur
/archives//html/TenTec/2005-03/msg00210.html (7,550 bytes)

27. Re: [TenTec] Argosy II Digital Display (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Sat, 12 Mar 2005 15:26:12 -0500
My Model 525-D has a problem with the last digit of the display flashing between characters when set on a frequency. I remember reading about a fix for this on one of the other models but can't remem
/archives//html/TenTec/2005-03/msg00296.html (7,858 bytes)

28. Re: [TenTec] First Time PTO Rebuild (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Thu, 24 Mar 2005 01:50:04 -0500
Rebuilding the PTO's will be the same for both rigs BUT the Corsair PTO is much easier to remove from the rig. The Omni-C PTO is tricky to remove... Ten-Tec will send you instructions on how to remov
/archives//html/TenTec/2005-03/msg00597.html (8,383 bytes)

29. Re: [TenTec] First Time PTO Rebuild (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Thu, 24 Mar 2005 11:07:03 -0500
Seems I saw such a thread. I tried about everything I could come up with to fix a gummed up PTO in a Triton 544, going so far as to heat it overnight on a steam radiator. Finally bit the bullet and o
/archives//html/TenTec/2005-03/msg00601.html (9,786 bytes)

30. Re: [TenTec] Zero beating. (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Fri, 25 Mar 2005 17:48:10 -0500
Nobody mistakes my brass key pounding, Perry. I agree that having everybody "zero beat" is bothersome. 73, Mike N4NT Amen Ken!! You have "raised THIS flag, and I salute it! :-) When two and three guy
/archives//html/TenTec/2005-03/msg00662.html (8,622 bytes)

31. Re: [TenTec] New Rig Suggestion (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Mon, 14 Feb 2005 21:49:18 -0500
Why $500. Why not $300? 73, Mike N4NT I find all the discussion of the Orion interesting and I think the Orion has it's place, but I think what is needed is an affordable starter radio. We need a rad
/archives//html/TenTec/2005-02/msg00387.html (11,784 bytes)

32. Re: [TenTec] mystery Ten-Tec Omni (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Mon, 21 Feb 2005 19:59:53 -0500
Hi, Scott-- To have 18 MHz capability, you will need to add a different rig. Because that Omni (whether B or C) uses a 9 MHz intermediate frequency, because the second harmonic of that is 18 MHz, bec
/archives//html/TenTec/2005-02/msg00580.html (9,632 bytes)

33. Re: [TenTec] mystery Ten-Tec Omni (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Tue, 22 Feb 2005 09:11:49 -0500
Hi, Ira You no doubt had problems. That you were unaware of them doesn't lessen them. One is seldom bothered by his own spurious emissions. The question is: had you known of the propensity of the Omn
/archives//html/TenTec/2005-02/msg00600.html (9,002 bytes)

34. Re: [TenTec] Which Airpax for Corsair II??? (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Fri, 14 Jan 2005 11:39:50 -0500
The trip current of the Ten-Tec supplies I've used is adjustable. Given your facts, I would use the lower current Airpax so long as it doesn't trip under normal conditions. 73, Mike N4NT I have an Ai
/archives//html/TenTec/2005-01/msg00483.html (8,055 bytes)

35. Re: [TenTec] Omni D faults cleared one remains (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Sun, 23 Jan 2005 11:05:41 -0500
If it's an oscillation, there should be RF output somewhere. Measure and see. I believe there is a bias adjustment for the PA transistors. I would suspect that it is set wrong, is dirty or there is s
/archives//html/TenTec/2005-01/msg00910.html (8,259 bytes)

36. Re: [TenTec] Corsair II vs Omni VI+ (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Fri, 10 Dec 2004 15:45:50 -0500
If you'll get an Omni-C or a Triton 544, you may like listening to either of them better than the Corsair II or the Omni IV+. 73, Mike N4NT I have been playing the last couple of days (nights) on 80&
/archives//html/TenTec/2004-12/msg00363.html (9,248 bytes)

37. Re: [TenTec] Triton 4 Question (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Sat, 11 Dec 2004 08:42:43 -0500
When the 242 remote VFO is used with the 544, the frequency is displayed on the rig regardless of where the frequency is generated. For this reason an additional frequency readout is not needed. I be
/archives//html/TenTec/2004-12/msg00395.html (9,093 bytes)

38. Re: [TenTec] FS: Paragon II corrected filter info (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Tue, 14 Dec 2004 23:21:07 -0500
Now that makes sense. We ought to rename "miles per hour" Newtons or Fords or anything. I'm going 65 Newtons ? Along these lines we could name "dollars per hour" ( a rate of pay ) as Greenspans. I ma
/archives//html/TenTec/2004-12/msg00584.html (8,921 bytes)

39. Re: [TenTec] List Blockage (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Wed, 15 Dec 2004 13:51:45 -0500
Hi, Al-- received nothing from this Ten-Tec reflector. When I checked email the morning of December 14, I received a flood of them. 73, Mike N4NT Has anyone experienced a lack of messages from the li
/archives//html/TenTec/2004-12/msg00607.html (7,982 bytes)

40. Re: [TenTec] Any issues with Corsair II --> SB-200 amp? (score: 1)
Author: "Mike Hyder -N4NT-" <mike.hyder.n4nt@charter.net>
Date: Fri, 17 Dec 2004 22:03:02 -0500
Harbach made a "soft key" circuit for my SB-220 (yes I know we're discussing the SB-200) that reduced the voltage / current needing to be switched to almost nothing. I've used that SB-220 for about 2
/archives//html/TenTec/2004-12/msg00651.html (14,823 bytes)


This search system is powered by Namazu