- 1. [RFI] Power Line Noise Specific to 15 meters (score: 1)
- Author: Pete Smith N4ZR <pete.n4zr@gmail.com>
- Date: Sun, 3 Oct 2021 16:01:21 -0400
- This is a bit of a puzzle, to me anyway. With my tribander pointed in one direction (west), I have extremely bad what sounds like line noise. This noise is not audible on 20 meters, on 10 meters, o
- /archives//html/RFI/2021-10/msg00012.html (7,672 bytes)
- 2. Re: [RFI] Power Line Noise Specific to 15 meters (score: 1)
- Author: Michael Carter <Mike.Carter@unh.edu>
- Date: Sun, 3 Oct 2021 20:19:23 +0000
- Pete, Does your noise remain constant in intensity/signal strength across the 15 meter band? If not, you may have a non-power line source to hunt. If you have an oscilloscope, place its probe across
- /archives//html/RFI/2021-10/msg00013.html (11,012 bytes)
- 3. Re: [RFI] Power Line Noise Specific to 15 meters (score: 1)
- Author: Mike Martin <mike@rfiservices.com>
- Date: Sun, 03 Oct 2021 20:04:01 -0400
- Couple of things that will change a noise from what's considered normal. The source of the noise or where the noise is radiating from to get to your antenna could be in a position that allows it to a
- /archives//html/RFI/2021-10/msg00016.html (8,642 bytes)
- 4. Re: [RFI] Power Line Noise Specific to 15 meters (score: 1)
- Author: Pete Smith N4ZR <pete.n4zr@gmail.com>
- Date: Sun, 3 Oct 2021 21:40:49 -0400
- Thanks, Mike - As to your latter point, I think this qualifies as line noise because it is present all across 10, 15 and 20, just at much lower amplitude except on 15, but it certainly could be a res
- /archives//html/RFI/2021-10/msg00017.html (8,967 bytes)
- 5. Re: [RFI] Power Line Noise Specific to 15 meters (score: 1)
- Author: "EDWARDS, EDDIE J via RFI" <rfi@contesting.com>
- Date: Mon, 4 Oct 2021 14:01:20 +0000
- Mike, You're statement that it's not likely is correct most the time (99.9%), but there are rare occasions when the hardware configuration doesn't follow the expected weather changes. Had one case wi
- /archives//html/RFI/2021-10/msg00018.html (9,224 bytes)
- 6. Re: [RFI] Power Line Noise Specific to 15 meters (score: 1)
- Author: Michael Carter <Mike.Carter@unh.edu>
- Date: Mon, 4 Oct 2021 14:31:42 +0000
- Thanks, Ed - those are good, notable exceptions to the general trend of rain/condensation shorting out the arc path/gap. We have some transformer primary bushings equipped with squirrel guards, but t
- /archives//html/RFI/2021-10/msg00019.html (9,796 bytes)