1. [RFI] Arc fault protection (score: 1)
Author: rick darwicki <n6pe@yahoo.com>
Date: Sat, 5 Jan 2013 09:40:41 -0800 (PST)
I remember when these first came out, building codes required them on the duplex outlet circuits to bedrooms so electric blankets didn't cause fires. Now a lot of states want them everywhere. Typical
/archives//html/RFI/2013-01/msg00046.html (6,989 bytes)

2. Re: [RFI] Arc fault protection (score: 1)
Author: Jim Brown <jim@audiosystemsgroup.com>
Date: Sat, 05 Jan 2013 10:15:19 -0800
Two important clarifications here. First, virtually all building codes in North America are based on NEC, which is written by a group of EEs from industry. It's a very good code. NEC is adopted by lo
/archives//html/RFI/2013-01/msg00047.html (8,278 bytes)

3. Re: [RFI] Arc fault protection (score: 1)
Author: "Roger (K8RI)" <k8ri@rogerhalstead.com>
Date: Sat, 05 Jan 2013 16:35:26 -0500
On 1/5/2013 12:40 PM, rick darwicki wrote: I remember when these first came out, building codes required them on the duplex outlet circuits to bedrooms so electric blankets didn't cause fires. Now a
/archives//html/RFI/2013-01/msg00049.html (8,812 bytes)

4. Re: [RFI] Arc fault protection (score: 1)
Author: Joe <wa6rkn@gmail.com>
Date: Sat, 5 Jan 2013 13:54:47 -0800
Here in Reno, in my house, certified for occupancy in 1988...There is a GFI device in each bathroom and in the kitchen. The downstairs GFI unit controls all the outlets in the garage. The kitchen GFI
/archives//html/RFI/2013-01/msg00051.html (8,400 bytes)

5. Re: [RFI] Arc fault protection (score: 1)
Author: Christopher Brown <cbrown@woods.net>
Date: Sat, 05 Jan 2013 13:12:02 -0900
The practical problem with AFCI (Arc Fault Circuit Interrupter) devices is that they are supposed to sense RF. Yes, there is a RF detector in there. AFCI devices are available in both AFCI only, and
/archives//html/RFI/2013-01/msg00052.html (11,192 bytes)

6. Re: [RFI] Arc fault protection (score: 1)
Author: Charles Coldwell <coldwell@gmail.com>
Date: Sat, 5 Jan 2013 19:04:01 -0500
Perhaps this explains why the ham whose transmissions were triggering the AFCI was not interested in troubleshooting this issue. -- Charles M. Coldwell, W1CMC "Turn on, log in, tune out" Belmont, Mas
/archives//html/RFI/2013-01/msg00054.html (7,677 bytes)

7. Re: [RFI] Arc fault protection (score: 1)
Author: Jim Brown <jim@audiosystemsgroup.com>
Date: Sun, 06 Jan 2013 00:02:52 -0800
I suspect that's an oversimplification. I can believe that there's a high pass filter in front of the detector, but any responsible design should include a reasonable high frequency limit. BUT -- it
/archives//html/RFI/2013-01/msg00057.html (8,434 bytes)

8. Re: [RFI] Arc fault protection (score: 1)
Author: Richard Battles <wb4byq@gmail.com>
Date: Sun, 6 Jan 2013 07:52:27 -0600
Just to say this, the sub panel in the house that i live in, has 7 Square D AFCI. i run two amps, on ssb. i have a yeasu fl-2100b and a Ameritron AL-80B. the antennas are with 30 to 40 feet from the
/archives//html/RFI/2013-01/msg00058.html (9,142 bytes)