I'm trying to make a 22 mile link happen on 2.4Ghz. Here is the set up: Site-A -- AP-1000 (tower mounted) with 10' of LMR-400 with a 180mw PRISM card to a 24dbi Connifer Grid dish (horizontal pol). S
What's your noise floor look like? If you have a -67db noise floor, you won't make that link happen. You might want to check noise floor first and see if you have any "clean channels" to work with. I
Bill The noise info that is reported on TurboCell is not correct with any prism 2.5 card. This is something KN says is an issue with the Prism MAC etc etc. Bottom line is its not correct. But the sig
The 180mW cards have better RX levels then the Orinocos as we are not using the Prism ref design, the RF sub system is better then others Prism cards on the market. But this would be a good test to s
Why are you using an amp w/ 180mw cards? Dan Metcalf Wireless Broadband Systems http://www.wbsysnet.com/ 877-685-0578 dan.metcalf@wbsysnet.com On up: to a mounted reorienting so at else next? -- [Thi
Noise has never been a problem here. I'm constantly amazed at how little RF there is on 2.4Ghz around my area. Lots of trees I suppose. I've tried this link on two channels thus far. I've tried a Lu
Yep, I tried a Lucent card thinking the same thing. But I've got another link that is driving the same brand/model amp with a 180mw card on an even shorter link and it works great. So I don't think
This is what I'm seeing exactly. Your 180mw Prism cards have better ears than the Lucents. I have two AP-1000's using your two of your 180mw cards in each. Both work great. The one at point-B has on
Ok good to know, if I remember the amp is good with 30mW to 100mW and with the cable loss this should be in the range. Sincerely Tony Morella Demarc Technology Group Office: 908-996-7995 Cell: 908-24
Bill What is the signal you are getting on the site that can see the remote? The numbers are not adding up somewhere. Sincerely Tony Morella Demarc Technology Group Office: 908-996-7995 Cell: 908-246
There isn't enough signal to get a number Tony. It doesn't report anything anyway. I don't think it is a metering problem. I was only able to even see the other side after much tinkering with the po
4.02+ Sincerely Tony Morella Demarc Technology Group Office: 908-996-7995 Cell: 908-246-9170 Fax: 908-847-0202 email: tony@demarctech.com http://www.demarctech.com Open Chat Server http://www.demarct
no That would be a COR-1100 w/ 4.1x as well? _______________________________________________ Karlnet mailing list Karlnet@WISPNotes.com http://lists.wispnotes.com/mailman/listinfo/karlnet
No the Orinoco version DOES NOT have Prism 2.5 drivers included. Sincerely Tony Morella Demarc Technology Group Office: 908-996-7995 Cell: 908-246-9170 Fax: 908-847-0202 email: tony@demarctech.com ht