- 1. R: SV: SV: [AMPS] Final.. (score: 1)
- Author: Maurizio Panicara" <i4jmy@iol.it (Maurizio Panicara)
- Date: Tue, 4 Jan 2000 19:17:28 +0100
- Once I've seen a grid driven amplifier in which a ferrite broadband transformer 50/200 ohm was used, probably to develop a bigger voltage across grid without increasing the driving power. The 200 ohm
- /archives//html/Amps/2000-01/msg00085.html (10,390 bytes)
- 2. R: SV: SV: [AMPS] Final.. (score: 1)
- Author: measures@vcnet.com (measures)
- Date: Tue, 4 Jan 2000 10:52:48 -0700
- The duty-cycle for SSB is pretty low, so the grid-termination resistor can be pretty smsll. Another factor is that tetrodes with handles typically have much air going through the vicinity. burning u
- /archives//html/Amps/2000-01/msg00088.html (9,712 bytes)