1. [Amps] ripple in HV ps (score: 1)
Author: "Partain, Chuck" <Chuck_Partain@maxtor.com>
Date: Wed, 8 Mar 2006 09:40:47 -0500
ok another easy question for you guru's what is an "acceptable" percentage for HVPS ripple? I see figures of up to 10% thought that was high, lets assume at operating current not into a R load but re
/archives//html/Amps/2006-03/msg00196.html (6,944 bytes)

2. Re: [Amps] ripple in HV ps (score: 1)
Author: HAROLD B MANDEL <ka1xo@juno.com>
Date: Wed, 8 Mar 2006 09:46:22 -0500
The 2006 ARRL Handbook recommends no greater than 3% ripple in anode supplies. Hal W4HBM _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.
/archives//html/Amps/2006-03/msg00197.html (6,215 bytes)

3. Re: [Amps] ripple in HV ps (score: 1)
Author: R@contesting.com;Measures <r@somis.org>
Date: Wed, 8 Mar 2006 09:05:26 -0800
A 4-1000A / 8166 with a 60 Hz, FWB, 7000v PS, using a 2uF filter C produces no detectable ripple on a SSB signal. Rich Measures, 805.386.3734, AG6K, www.somis.org ____________________________________