- 1. [Amps] diodes for motor driven vacuum variable (score: 1)
- Author: Jim Hoge <knowkode@verizon.net>
- Date: Sat, 25 Aug 2012 20:27:31 -0700 (PDT)
- Hi all, I have a vacuum variable driven by a 28v motor. Perhaps the assembly had come out of some Harris equipment, it certainly looks Mil Spec. As part of the limit switch assembly, there are 3 diod
- /archives//html/Amps/2012-08/msg00431.html (7,087 bytes)
- 2. Re: [Amps] diodes for motor driven vacuum variable (score: 1)
- Author: Larry Benko <xxw0qe@comcast.net>
- Date: Sat, 25 Aug 2012 22:09:15 -0600
- Jim, Let's assume for a minute that there are only 2 diodes and the 3rd one is maybe something like a zener as only 2 diodes are needed for the usual limit switch circuitry. Also I am assuming that t
- /archives//html/Amps/2012-08/msg00432.html (8,003 bytes)
- 3. Re: [Amps] diodes for motor driven vacuum variable (score: 1)
- Author: Radio WC6W <wc6w_amps@yahoo.com>
- Date: Mon, 27 Aug 2012 08:19:55 -0700 (PDT)
- Hi Jim, A reasonable guess would be some manufacturer's house number for a 1N4245: 1 amp @ 200V PIV. Something from the 1N400X series, 1N4003 or 1N4004 would be fine substitutes. 73 & Good morning, M
- /archives//html/Amps/2012-08/msg00470.html (8,872 bytes)