1. Re: [Amps] which HV connector to use?] (score: 1)
Author: "Edward Swynar" <gswynar@durham.net>
Date: Fri, 15 Jan 2010 13:47:15 -0500
Hi Rob, Yes, as Alex correctly points-out, this topic HAS been round the oval at least once before...! Hi Hi ...And as before, I *still* maintain that you can't do much better than to employ good-qua
/archives//html/Amps/2010-01/msg00257.html (11,395 bytes)

2. Re: [Amps] which HV connector to use?] (score: 1)
Author: "Dr. David Kirkby" <david.kirkby@onetel.net>
Date: Thu, 21 Jan 2010 13:14:59 +0000
With all due respect, using SO239/PL259 seems about the silliest suggestion I have ever heard. I'm not saying the insulation may be insufficient on some models made in the USA when they are mated, bu
/archives//html/Amps/2010-01/msg00268.html (8,302 bytes)

3. Re: [Amps] which HV connector to use?] (score: 1)
Author: "Edward Swynar" <gswynar@durham.net>
Date: Thu, 21 Jan 2010 09:24:53 -0500
"...With all due respect, using SO239/PL259 seems about the silliest suggestion I have ever heard. I'm not saying the insulation may be insufficient on some models made in the USA when they are mated
/archives//html/Amps/2010-01/msg00297.html (8,359 bytes)

4. Re: [Amps] which HV connector to use?] (score: 1)
Author: "Bill VanAlstyne W5WVO" <w5wvo@cybermesa.net>
Date: Sat, 23 Jan 2010 21:34:56 -0700
I have a clear recollection of being told, years ago, that the ORIGINAL design use model for the UHF connector series (PL-259/SO-239) was for connecting high DC supply voltages between transmitter mo
/archives//html/Amps/2010-01/msg00298.html (10,554 bytes)

5. Re: [Amps] which HV connector to use?] (score: 1)
Author: "Hardy Landskov" <n7rt@cox.net>
Date: Sat, 23 Jan 2010 22:27:31 -0700
Just for the record, we used RG8 years ago at K6UA's to run high voltage everywhere to each amplifier from one central power supply. Worked fine with SO239/PL259 connectors. The insulation is fine. T
/archives//html/Amps/2010-01/msg00299.html (12,173 bytes)

6. Re: [Amps] which HV connector to use?] (score: 1)
Author: "Gary Hinson" <Gary@isect.com>
Date: Sun, 24 Jan 2010 21:01:23 +1300
Some people are just lucky at Russian roulette. Others prefer to avoid avoidable risks. Each to his own. FWIW I'm glad to hear about safer alternatives, and would be especially interested to hear abo
/archives//html/Amps/2010-01/msg00301.html (13,911 bytes)