1. [Amps] Vacuum Variable Fatigue Failures (score: 1)
Author: Pat Barthelow <aa6eg@hotmail.com>
Date: Sat, 16 Feb 2008 11:19:33 -0800
Folks, I was looking closely at the mechanical marvel that is a Jennings Vacuum variable capacitor. I am wondering about whether the copper bellows arrangement that allows extension and contraction o
/archives//html/Amps/2008-02/msg00105.html (9,949 bytes)

2. Re: [Amps] Vacuum Variable Fatigue Failures (score: 1)
Author: ToddRoberts2001@aol.com
Date: Sat, 16 Feb 2008 16:01:09 EST
I was looking closely at the mechanical marvel that is a Jennings Vacuum variable capacitor. I am wondering about whether the copper bellows arrangement that allows extension and contraction of the "
/archives//html/Amps/2008-02/msg00106.html (7,031 bytes)

3. Re: [Amps] Vacuum Variable Fatigue Failures (score: 1)
Author: "Saandy Eban" <alexeban@gmail.com>
Date: Sun, 17 Feb 2008 08:07:38 +0200
.all I can tell you is that, in 40 years in the profession, I never saw one with cracked bellows The only fault I ever saw was drying up of the tuning screw, with an attendant screech of the worst ki
/archives//html/Amps/2008-02/msg00110.html (9,034 bytes)

4. [Amps] Vacuum Variable Fatigue Failures (score: 1)
Author: "Dave Bowker" <dbowker@mail.sjv.net>
Date: Sat, 16 Feb 2008 15:29:44 -0500
The mechanical life expectancy of any vacuum variable capacitor (independent of manufacturer) is dependent upon (1) length of stroke of the bellows, (2) speed of operation or mechanical cycling of th