Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Amps\]\s+Vac\s+relay\s+coils\s+in\s+series\s+\?\s*$/: 6 ]

Total 6 documents matching your query.

1. [Amps] Vac relay coils in series ? (score: 1)
Author: "jim.thom jim.thom@telus.net" <jim.thom@telus.net>
Date: Wed, 16 Mar 2022 10:01:23 -0700
I'm installing 3x vac relay's into an amplifier. (Input, output, and cut off bias). Coils are available for both 12 vdc ( 80 ohms)....and also 26.5 vdc ( 335 ohms). The amp has to be able to handle a
/archives//html/Amps/2022-03/msg00021.html (7,992 bytes)

2. Re: [Amps] Vac relay coils in series ? (score: 1)
Author: Jim W7RY <jimw7ry@gmail.com>
Date: Wed, 16 Mar 2022 16:46:14 -0500
Ive never had a coil fail on one of these types of vacuum relays. Had a NC contact fail on a RJ1A. 73, Jim W7RY On 3/16/2022 12:01 PM, jim.thom jim.thom@telus.net wrote: I'm installing 3x vac relay's
/archives//html/Amps/2022-03/msg00023.html (8,940 bytes)

3. Re: [Amps] Vac relay coils in series ? (score: 1)
Author: Roy <k6xk@ncn.net>
Date: Thu, 17 Mar 2022 07:33:52 -0500
Same here... 73, Roy  K6XK Had a NC contact fail on a RJ1A. 73, Jim W7RY What is the 'normal'  failure mode for a vac relay ?   Is it the  coil that goes open, or does the armature inside  bind up, a
/archives//html/Amps/2022-03/msg00024.html (7,787 bytes)

4. Re: [Amps] Vac relay coils in series ? (score: 1)
Author: N1BUG <paul@n1bug.com>
Date: Thu, 17 Mar 2022 08:36:45 -0400
Me too. Never had a coil fail but have had contacts fail on RJ1A relays. 73, Paul N1BUG 73, Roy  K6XK Had a NC contact fail on a RJ1A. 73, Jim W7RY What is the 'normal'  failure mode for a vac relay
/archives//html/Amps/2022-03/msg00025.html (8,219 bytes)

5. Re: [Amps] Vac relay coils in series ? (score: 1)
Author: MU 4CX250B <4cx250b@miamioh.edu>
Date: Thu, 17 Mar 2022 07:07:35 -0700
Me also. Ive had one coil failure caused by my clumsy effort to clean a coil terminal, and one stuck NC contact, likely caused by my trying to switch a DC voltAge (the RJ1A is intended for RF switchi
/archives//html/Amps/2022-03/msg00026.html (9,060 bytes)

6. Re: [Amps] Vac relay coils in series ? (score: 1)
Author: "Paul Christensen" <w9ac@arrl.net>
Date: Thu, 17 Mar 2022 10:31:58 -0400
Only N/C failures here from my RJ-1 and HC-1 relays. My Alpha 77Dx needs a replacement; the failure manifests as intermittent receive sensitivity. The Alpha 77Dx has sequenced hot-switch protection.
/archives//html/Amps/2022-03/msg00027.html (7,520 bytes)


This search system is powered by Namazu