1. [Amps] Tl-922 plate meter protection (score: 1)
Author: slonim aron <as1935@012.net.il>
Date: Wed, 23 Apr 2008 15:33:15 +0300
Hi Wonder whats the best way to protect the plate meter against damage during "vhf parasitic". Thanks. Aron 4x1fq. _______________________________________________ Amps mailing list Amps@contesting.co
/archives//html/Amps/2008-04/msg00268.html (6,569 bytes)

2. Re: [Amps] Tl-922 plate meter protection (score: 1)
Author: Missouri Guy <n0tt1@juno.com>
Date: Wed, 23 Apr 2008 14:27:11 +0000
Aron, A diode across the meter will usually work on sensitive meters. Connect the diode's cathode to the negative terminal so it will conduct if the voltage across the meter (and diode) exceeds about
/archives//html/Amps/2008-04/msg00270.html (7,283 bytes)

3. Re: [Amps] Tl-922 plate meter protection (score: 1)
Author: Kees - pa7two <pa7two@hotmail.com>
Date: Wed, 23 Apr 2008 15:13:08 +0000
Better is to use two diodes, crossed, between the two meter connection points on the back of the meter. Diodes can pick up rf and start generating themselfs... 3Amp/1000 volt is OK. Vy 73, de Kees -
/archives//html/Amps/2008-04/msg00271.html (8,861 bytes)