- 1. [Amps] Titan quits query (score: 1)
- Author: Charles Harpole <k4vud@hotmail.com>
- Date: Wed, 24 Jun 2009 11:22:21 +0000
- Ten Tec Titan, the first model, was operating ok on 20 m ssb. I switched to CW, same drive power (40w) and when I looked a few seconds later at the amp, it was completely off. Now, it does not come o
- /archives//html/Amps/2009-06/msg00107.html (7,478 bytes)
- 2. Re: [Amps] Titan quits query (score: 1)
- Author: Alek Petkovic <vk6apk@bigpond.com>
- Date: Wed, 24 Jun 2009 19:31:09 +0800
- Talk to Sam and/or Martin. They should be able to sort it. 73, Alek VK6APK http://www.qrz.com/vk6apk http://www.qrz.com/vk6py _______________________________________________ Amps mailing list Amps@co
- /archives//html/Amps/2009-06/msg00108.html (8,185 bytes)
- 3. Re: [Amps] Titan quits query (score: 1)
- Author: "Jim Brown" <jim@audiosystemsgroup.com>
- Date: Wed, 24 Jun 2009 15:07:05 -0700
- Two fuses on the power supply. They will occasionally blow, with the symptoms noted. I use standard 3AG or 3AB 15A fast blow fuses. They blow in pairs. I believe the manual calls for 20A, but when so
- /archives//html/Amps/2009-06/msg00110.html (7,457 bytes)
This search system is powered by