Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Amps\]\s+Swan\s+Mark\s+1\s+Meter\s+Problem\s*$/: 3 ]

Total 3 documents matching your query.

1. [Amps] Swan Mark 1 Meter Problem (score: 1)
Author: ko4nrbs@yahoo.com (Bill Smith)
Date: Mon, 3 Jun 2002 06:28:35 -0700 (PDT)
My Mark 1 meter will not indicate anything at all. I have traced all the wiring throughout and did continuity checks but can't find anything wrong. How can I test the meter without damaging the movem
/archives//html/Amps/2002-06/msg00016.html (6,893 bytes)

2. [Amps] Swan Mark 1 Meter Problem (score: 1)
Author: stevek@jmr.com (Steve Katz)
Date: Tue, 4 Jun 2002 09:01:24 -0700
I think the Mark 1 used a single meter for all functions including plate current, grid current and plate voltage. If so, there's some fancy switching going on, there. Without the switch and the combi
/archives//html/Amps/2002-06/msg00019.html (8,543 bytes)

3. [Amps] Swan Mark 1 Meter Problem (score: 1)
Author: 2@mail.vcnet.com (Richard)
Date: Tue, 4 Jun 2002 16:51:12 -0700
Apply a known current through the meter current shunts resistors and check the accuracy of the grid and the plate/anode current meters. - R. L. Measures, a.k.a. Rich..., 805.386.3734,AG6K, www.vcnet
/archives//html/Amps/2002-06/msg00026.html (6,896 bytes)


This search system is powered by Namazu