- 1. [Amps] SHV connectors... (score: 1)
- Author: PY1NB - Felipe Ceglia <felipeceglia2@gmail.com>
- Date: Tue, 12 Feb 2013 13:46:04 -0200
- Hi folks, I cannot find any reasonable priced source for RG8 sized SHV connectors. The fair priced are these ones, from a chinese online store: http://www.rfsupplier.com/straight-plug-crimp-5000v-cab
- /archives//html/Amps/2013-02/msg00095.html (7,682 bytes)
- 2. Re: [Amps] SHV connectors... (score: 1)
- Author: "Jim Garland" <4cx250b@miamioh.edu>
- Date: Wed, 13 Feb 2013 12:17:40 -0700
- Felipe, I think those connectors (reverse-polarity SHV-BNC) are intended for RG6, which I believe may be a larger diameter than RG142 (but more flexible). I think RG6 Quad Shield is very high quality
- /archives//html/Amps/2013-02/msg00103.html (9,551 bytes)
- 3. Re: [Amps] SHV connectors... (score: 1)
- Author: PY1NB - Felipe Ceglia <felipeceglia2@gmail.com>
- Date: Fri, 15 Feb 2013 08:31:52 -0200
- Hi Jim, Thanks for reply. I will give a try for the chinese connectors. I am afraid of RG58, as by it specs its limit is 1900VRMS. 73, Felipe Ceglia - PY1NB -- PR1T team member /// Rio DX Group membe
- /archives//html/Amps/2013-02/msg00118.html (10,855 bytes)
- 4. Re: [Amps] SHV connectors... (score: 1)
- Author: "Carl" <km1h@jeremy.mv.com>
- Date: Fri, 15 Feb 2013 19:59:27 -0500
- With a quality mil spec RG-58A there should be no problem as Ive hipotted to 5000V and have to agree with Jim. RG-58A has a stranded center conductor and is very flexible and Ive used for almost 25 y
- /archives//html/Amps/2013-02/msg00126.html (12,147 bytes)
- 5. Re: [Amps] SHV connectors... (score: 1)
- Author: Steve Thompson <g8gsq72@gmail.com>
- Date: Sat, 16 Feb 2013 08:39:50 +0000
- I think the 1900V rating applies under circumstances which are very different from using the cable with SHV connectors. The breakdown voltage for polyethylene is something around 20kV/mm. I have test
- /archives//html/Amps/2013-02/msg00130.html (8,042 bytes)