Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Amps\]\s+SB220\s+Odd\s+problem\:\s+UPDATE\s*$/: 2 ]

Total 2 documents matching your query.

1. [Amps] SB220 Odd problem: UPDATE (score: 1)
Author: Shane Youhouse <kd6vxi@gmail.com>
Date: Thu, 12 May 2011 07:45:52 -0700
Finally got down to brass tacks on my SB220 (ie, got enough done to where I had some time). Grid current I meter would read 30 mils, keyed, NO tubes. Read the value of the .82 ohm shunt, its 33 ohms.
/archives//html/Amps/2011-05/msg00083.html (7,724 bytes)

2. Re: [Amps] SB220 Odd problem: UPDATE (score: 1)
Author: "Carl" <km1h@jeremy.mv.com>
Date: Thu, 12 May 2011 14:23:13 -0400
10pf 1Kv SM Shane or you can use a 5KV RF doorknob as those are often cheaper since no one has a use for such a low value. It goes between 40-20 right at the switch. For the switch use brass hardware
/archives//html/Amps/2011-05/msg00085.html (9,094 bytes)


This search system is powered by Namazu