References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Amps\]\s+SB220\s+Meter\s+blown\.\.\.follow\s+up\s+hope\s*$/: 7 ]

Total 7 documents matching your query.

1. Re: [Amps] SB220 Meter blown...follow up hope (score: 1)
Author: Artek Manuals <Manuals@ArtekManuals.com>
Date: Fri, 15 May 2020 13:45:30 -0400
With nothing else to loose IT removed the meter and found that ther are TWO resistors inside. One is in parallel with the meter movement and the other is in series. Those both have been "toasted"  a
/archives//html/Amps/2020-05/msg00012.html (10,929 bytes)

2. Re: [Amps] SB220 Meter blown...follow up hope (score: 1)
Author: Steven Katz <stevek@jmr.com>
Date: Fri, 15 May 2020 17:53:53 +0000
Why not use a VOM on a R x100 scale or something to connect directly across the meter (with no resistors in the circuit) by cutting the shunt and bypassing the series resistor, to confirm the movemen
/archives//html/Amps/2020-05/msg00013.html (11,165 bytes)

3. Re: [Amps] SB220 Meter blown...follow up hope (score: 1)
Author: "Gary Schafer" <garyschafer@largeriver.net>
Date: Fri, 15 May 2020 13:59:46 -0500
73 Gary K4FMX _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps
/archives//html/Amps/2020-05/msg00015.html (12,934 bytes)

4. Re: [Amps] SB220 Meter blown...follow up hope (score: 1)
Author: Paul Kraemer <elespe@lisco.com>
Date: Fri, 15 May 2020 14:12:57 -0500
That will certainly test the meter movement!  It will pin hard once that then you will know it is bad. NEVER TEST A METER MOVEMENT WITH A OHMMETER! Paul K0UYA With nothing else to loose IT removed th
/archives//html/Amps/2020-05/msg00016.html (11,373 bytes)

5. [Amps] SB220 Meter blown...follow up hope (score: 1)
Author: "Jim Thomson" <jim.thom@telus.net>
Date: Sat, 16 May 2020 07:51:34 -0700
<That will certainly test the meter movement!? It will pin hard once that <then you will know it is bad. <NEVER TEST A METER MOVEMENT WITH A OHMMETER! <Paul K0UYA movements..and they were 0- 1 ma typ
/archives//html/Amps/2020-05/msg00027.html (7,139 bytes)

6. Re: [Amps] SB220 Meter blown...follow up hope (score: 1)
Author: gudguyham--- via Amps <amps@contesting.com>
Date: Sat, 16 May 2020 20:42:21 +0000 (UTC)
I measure meters with my digital ohm meter at least a few times a week and have been since I had high impedance ohm meters.  Never blew up a meter yet.  Of course you have to know how to do it. <That
/archives//html/Amps/2020-05/msg00030.html (8,460 bytes)

7. Re: [Amps] SB220 Meter blown...follow up hope (score: 1)
Author: Jim <jimw7ry@gmail.com>
Date: Sat, 16 May 2020 20:11:18 -0500
Agreed Lou. Thanks 73 Jim W7RY <That will certainly test the meter movement!? It will pin hard once that <then you will know it is bad. <NEVER TEST A METER MOVEMENT WITH A OHMMETER! <Paul K0UYA ma  t
/archives//html/Amps/2020-05/msg00031.html (8,963 bytes)