- 1. [Amps] SB-220 no output (score: 1)
- Author: Warren Volz <warren@warrenvolz.com>
- Date: Tue, 25 Jul 2017 00:59:54 -0600
- All, I ran into another hurdle with the SB-220 and am hoping someone has some wisdom. If I run RF through the AMP without power applied the relative power meter works and I can match my dummy load wi
- /archives//html/Amps/2017-07/msg00102.html (7,266 bytes)
- 2. Re: [Amps] SB-220 no output (score: 1)
- Author: Glen Zook via Amps <amps@contesting.com>
- Date: Tue, 25 Jul 2017 13:47:41 +0000 (UTC)
- The meter reads "relative" power and, as such, the meter calibration has no meaning in terms of actual power output other than a higher reading, at any particular setting of the "sensitivity" control
- /archives//html/Amps/2017-07/msg00103.html (8,262 bytes)
- 3. Re: [Amps] SB-220 no output (score: 1)
- Author: Warren Volz <warren@warrenvolz.com>
- Date: Tue, 25 Jul 2017 12:29:59 -0600
- Ah! Yes ok, so it's only to give you a general idea on the power not actual numbers. That explains it. -Warren _______________________________________________ Amps mailing list Amps@contesting.com ht
- /archives//html/Amps/2017-07/msg00104.html (8,727 bytes)
- 4. [Amps] SB-220 no output (score: 1)
- Author: "Jim Thomson" <jim.thom@telus.net>
- Date: Wed, 26 Jul 2017 09:35:46 -0700
- <Ah! <Yes ok, so it's only to give you a general idea on the power not actual <numbers. That explains it. <-Warren tune and load controls for max output. It is NOT a wattmeter. Its a tuning aid...tha
- /archives//html/Amps/2017-07/msg00105.html (8,910 bytes)