Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Amps\]\s+I\s+need\s+advice\s+on\s+a\s+TL\-922\s+with\s+Harbach\s+Soft\-Start\s+module\s*$/: 3 ]

Total 3 documents matching your query.

1. [Amps] I need advice on a TL-922 with Harbach Soft-Start module (score: 1)
Author: "Dave G. ve9cb@rac.ca" <ve9cb@rac.ca>
Date: Thu, 24 Jan 2019 11:41:55 +0000 (UTC)
Hello all: I have a Kenwood TL-922 with a Harbach Soft-Start module installed. Normally, I run my amp from 220vac, but I am currently on a contest expedition in Labrador (Zone 2) and I have to run it
/archives//html/Amps/2019-01/msg00114.html (8,053 bytes)

2. Re: [Amps] I need advice on a TL-922 with Harbach Soft-Start module (score: 1)
Author: Jim <jimw7ry@gmail.com>
Date: Thu, 24 Jan 2019 19:03:22 -0600
I'd be glad to help. Do you have a TL922 schematic? Get out and lets take a look. Do you want to call me on the phone? Thanks 73 Jim W7RY On 1/24/2019 5:41 AM, Dave G. ve9cb@rac.ca wrote: Hello all:
/archives//html/Amps/2019-01/msg00118.html (8,961 bytes)

3. Re: [Amps] I need advice on a TL-922 with Harbach Soft-Start module (score: 1)
Author: Victor Rosenthal 4X6GP <k2vco.vic@gmail.com>
Date: Fri, 25 Jan 2019 05:33:53 +0200
The fan in the 922 is a 120v fan. It runs off of half the primary when the amp is configured for 220-240. There is a somewhat complicated circuit that keeps it running for a while after the amp is sh
/archives//html/Amps/2019-01/msg00120.html (9,226 bytes)