- 1. [Amps] I need advice on a TL-922 with Harbach Soft-Start module (score: 1)
- Author: "Dave G. ve9cb@rac.ca" <ve9cb@rac.ca>
- Date: Thu, 24 Jan 2019 11:41:55 +0000 (UTC)
- Hello all: I have a Kenwood TL-922 with a Harbach Soft-Start module installed. Normally, I run my amp from 220vac, but I am currently on a contest expedition in Labrador (Zone 2) and I have to run it
- /archives//html/Amps/2019-01/msg00114.html (8,053 bytes)
- 2. Re: [Amps] I need advice on a TL-922 with Harbach Soft-Start module (score: 1)
- Author: Jim <jimw7ry@gmail.com>
- Date: Thu, 24 Jan 2019 19:03:22 -0600
- I'd be glad to help. Do you have a TL922 schematic? Get out and lets take a look. Do you want to call me on the phone? Thanks 73 Jim W7RY On 1/24/2019 5:41 AM, Dave G. ve9cb@rac.ca wrote: Hello all:
- /archives//html/Amps/2019-01/msg00118.html (8,961 bytes)
- 3. Re: [Amps] I need advice on a TL-922 with Harbach Soft-Start module (score: 1)
- Author: Victor Rosenthal 4X6GP <k2vco.vic@gmail.com>
- Date: Fri, 25 Jan 2019 05:33:53 +0200
- The fan in the 922 is a 120v fan. It runs off of half the primary when the amp is configured for 220-240. There is a somewhat complicated circuit that keeps it running for a while after the amp is sh
- /archives//html/Amps/2019-01/msg00120.html (9,226 bytes)
This search system is powered by