- 1. [Amps] Heath SB1000 issue (score: 1)
- Author: "Van K7VS" <wa7fab@cdsnet.net>
- Date: Sat, 22 Mar 2008 14:36:14 -0700
- Plate voltage fine, key xmt relay and have about 50 ma. resting current. Apply 10 watts drive and the 3-500Z (which looks new!) the plate begins turning cherry red. Didn't have another 3-500Z emiac (
- /archives//html/Amps/2008-03/msg00209.html (6,965 bytes)
- 2. Re: [Amps] Heath SB1000 issue (score: 1)
- Author: "jeremy-ca" <km1h@jeremy.mv.com>
- Date: Sat, 22 Mar 2008 20:16:48 -0400
- 1. What was the plate and grid currents with the 10W drive? 2. Was any output registering as you tried to tune? It sounds like it is taking off; has it ever worked? Carl KM1H ________________________
- /archives//html/Amps/2008-03/msg00211.html (8,482 bytes)